EcoStar Auto works in auto as well as in fixed CPAP mode.In auto-mode, it automatically adjusts the pressure based on the detected respiratory events (inspiratory flow limitations, snoring, and residual apneas/hypopneas).
When the patient removes the mask, the pressure drops to the minimum level in just a few seconds. The device turns off after 30 minutes if the therapy is not resumed.
The ‘Auto-on’ function allows the patient to start the treatment with a single breath in the mask. The device can be started at any time by pushing the on/off button.
The intelligent ramp function (I-Ramp) makes it possible to start the treatment at an adjustable, more comfortable pressure (the ‘comfort pressure’), making falling asleep easier and more comfortable. It also optimizes the treatment efficacy by adapting the time in ramp to the detection of respiratory events that indicate that the patient is asleep. Once the device detects respiratory events (indicating that the patient is asleep), it will gradually and comfortably increase the pressure to reach the prescribed pressure or switch on the auto-algorithm depending on the selected mode. As the total duration of the ramp will be reduced, patients spend more time at effective pressure improving their overall compliance.
Choose any type of mask or tubing! Versatility and flexibility were never easier thanks to our advance resistance control. This technology will ensure that the prescribed pressure is delivered at the patients interface at all times regardless of the configuration of the pneumatic pathway (mask type, diameter and length of the circuit and the presence or absence of a humidifier).
EcoStar Auto is compatible with the OxyLink module (which synchronises oximetry data) and can be linked to the remote tracking platform SEFAMConnect.
CC+ makes the patient's breathing more comfortable during the inspiratory (pressure increase) and expiratory phases (pressure decrease) without the need to pre-set the level of pressure relief. CC+ is fully automatic and adapts to the respiratory cycles of any patient without compromising the treatment efficacy. Activate this ‘cruise control’ for enhanced comfort.
EcoStar Auto is compatible with the GKH2O heated humidifier.
A cigarette-lighter cable is available as an accessory.
Mode | Pressure delivered | Max flow | Ramp time | Noise level | Dimensions | Weight |
---|---|---|---|---|---|---|
CPAP, Auto-CPAP | 4 to 20 cm H2O adjustable in 0,5 cm H2O increments | 150 lpm at 20 cm H2O | Adjustable from 0 to 45mn | 27 dBA | D x W x H: 23 x 14 x 8 cm | 750 g without power supply |